790602 IMU-MGS - Transient 5kV Burst & Surge Generator
IMU-MGS

IMU-MGS

Compact Transient 5KV EFT/Burst and SURGE generator

Compact generator for EFT/Burst and SURGE up to 5KV. Integrated 16 A CDN. Extend with ESD, Dips/Interrupts and Common Mode.

Modular test generator with colour touch screen and intuitive software. An integrated help with graphics guide the user through fast and efficient setup and operation. Each generator can be extended on site with up to 10 test types. Configurations for IEC / EN and ANSI test requirements can include Surge (CWG) and EFT up to 5kV. DIPS/Interrupts, variations, Common Mode, Differential Mode and ESD further enhance the generator creating a compact test solution. A test library of basic and generic requirements is included as standard. The integrated web server enables access to test report and setup files from any internet browser.

 Pulses

  • Surge / CWG up to 5kV
  • EFT / Burst up to 5kV
  • Common Mode 35V/330V
  • AC & DC Interrupts up to 16A
  • AC DIPS & Variation up to 16A
  • Differential Mode voltage / current
  • ESD up to 16kV

 Documents

 Conducted Immunity

 Your Benefits

  • 4 kV or 5 kV Impulses
  • Compact portable test generator
  • Integrated Variac
  • Integrated Common Mode
  • Control of ESD
  • Control of Differential Mode
  • DIPS / Interrupts & Variations
  • AC & Impulse Magnetic Fields

 Product Options

 Surge / CWG up to 5kV
  EFT / Burst up to 5kV
  Common Mode 35V/330V
  AC / DC Interrupts up to 75A
  AC DIPS / Variation up to 16A
  Differential Mode voltage / current
  ESD up to 16kV


esd_header IMU-MGS - Transient 5kV Burst & Surge Generator
Electrostatic discharge testing
app_immunity_600x202 IMU-MGS - Transient 5kV Burst & Surge Generator
Basic- and Product standard requirements & Solutions
Compact generator for EFT/Burst and SURGE up to 5KV. Integrated 16 A CDN. Extend with ESD, Dips/Interrupts and Common Mode.
Compact Transient 5KV EFT/Burst and SURGE generator
surge, burst, burst generator, surge generator, eft generator, dips, variations, interrupts, common mode, differential mode, magnetic field, iec, conducted immunity, test generator, emc, imu
Surge / CWG up to 5kV
EFT / Burst up to 5kV
Common Mode 35V/330V
AC / DC Interrupts up to 75A
AC DIPS / Variation up to 16A
Differential Mode voltage / current
ESD up to 16kV
  • Surge / CWG up to 5kV
  • EFT / Burst up to 5kV
  • Common Mode 35V/330V
  • AC & DC Interrupts up to 16A
  • AC DIPS & Variation up to 16A
  • Differential Mode voltage / current
  • ESD up to 16kV

IMU-MGS - Your Benefits


  • Line voltages L to L=690V

  • DC Max. 500V



109215
IEC 61000-4-2
  • IEC 61000-4-4
  • IEC 61000-4-5
  • IEC 61000-4-8
  • IEC 61000-4-9
  • IEC 61000-4-11
  • IEC 61000-4-16
  • IEC 61000-4-19
  • IEC 61000-4-29
  • IEC 61000-6-1
  • IEC 61000-6-2
  • IEC 60255-26
  • IEC 60571
  • EN 50121-3-2
  • EN 50121-4
  • EN 50155
  • IEC 61851-22
  • IEC 61851-21-2
  • IEC 60601-1-2
  • Conducted Immunity,ESD testing
    IMU (Com.Mode),IMU (Diff.Mode),IMU (Dips,IMU (EFT),IMU (ESD),IMU (Magnetic Field),IMU (Surge & CWG),IMU (Variations)
    IEC 61000-4-4
    IEC 61000-4-5
    IEC 61000-4-12
    Programmable, automated coupling
    Line voltages L to L=690V
  • DC Max. 500V